Copper winding wires are designed for winding of electric motors stators, transformers, electromagnetic relay, coils of oscillating circuits of products with maximum thermal and mechanical loads and also for winding of electric machines and devices
Copper winding wires can be used either for mechanical or manual winding.
The wires are manufactured on the modern equipment of the Austrian manufacturer MAG AG using the insulating materials of the French company IVA ESSEX SAS. Packing of the final products is performed on spools K-125/K-250 according to IEC 60264-2 (winding up to 20 kg), placed on the wooden pallets and tied up with polypropylene band.
Name | Grade | Technical specifications and standards | Temperature index | Insulation type | Diameter range, mm | Thermoplasticity, °C | Heat shock, °C | Properties and applications |
Round copper wire with enamel insulation on the basis of polyurethanes | ПЕВТЛ-1; ПЕВТЛ-2 | ТУ У 27.3-38456790-008:2017 | 130
180 |
Polyurethane | 0,06-1,60 | 240±5 | 200±5 | For electrical and radio engineering products.
Tinned at |
Copper winding wires are designed for winding of electric motors stators, transformers, electromagnetic relay, coils of oscillating circuits of products with maximum thermal and mechanical loads and also for winding of electric machines and devices
Copper winding wires can be used either for mechanical or manual winding.
The wires are manufactured on the modern equipment of the Austrian manufacturer MAG AG using the insulating materials of the French company IVA ESSEX SAS. Packing of the final products is performed on spools K-125/K-250 according to IEC 60264-2, A-200/A-400 according to IEC 60264-3 (winding up to 200 kg), placed on the wooden pallets and tied up with polypropylene band.
Name | Grade | Technical specifications and standards | Temperature index | Insulation type | Diameter range, mm | Thermoplasticity, °C | Heat shock, °C | Properties and applications |
Round copper winding wire with enamel insulation on the basis of polyester or polyetherimide | ПЕТ-155; ПЕТ-180 | ТУ У 27.3-38456790-005:2017 | 155
180 |
Polyester or polyetherimide | 0,06÷2,5
0,06÷2,5 |
240±5
265±5 |
200±5 | For winding of electric machines, apparatuses and devices |
Technical requirements according to ДСТУ EN 1977:2009
Copper grade | Diameter, mm | Name of indicators | Norm according to ДСТУ |
Cu-ETP |
8,0±0,4 12,7±0,4 |
Relative elongation, %, not less | 30 |
Specific electrical resistance at the temperature 200С, mkOHM/m, not more | 0,01724 | ||
Cu-OF |
8,0±0,4 12,5±0,4 16,0±0,4 18,0±0,4 20,0±0,6 22,0±0,6 24,0±0,6 |
Relative elongation, %, not less | 30 |
Specific electrical resistance at the temperature 200С, mkOHM/m, not more | 0,01724 | ||
CuSn 0,01(OF) |
8,0±0,4 12,5±0,4 16,0±0,4 18,0±0,4 20,0±0,6 22,0±0,6 24,0±0,6 |
Relative elongation, %, not less | 30 |
Specific electrical resistance at the temperature 200С, mkOHM/m, not more | 0,01724 | ||
CuAg 0,10(OF) |
8,0±0,4 12,5±0,4 16,0±0,4 18,0±0,4 20,0±0,6 22,0±0,6 24,0±0,6 |
Relative elongation, %, not less | 30 |
Specific electrical resistance at the temperature 200С, mkOHM/m, not more | 0,01724 |
Copper winding wires are designed for winding of electric motors stators, transformers, electromagnetic relay, coils of oscillating circuits of products with maximum thermal and mechanical loads and also for winding of electric machines and devices
Copper winding wires can be used either for mechanical or manual winding.
The wires are manufactured on the modern equipment of the Austrian manufacturer MAG AG using the insulating materials of the French company IVA ESSEX SAS. Packing of the final products is performed on spools K-125/K-250 according to IEC 60264-2 (winding up to 20 kg), placed on the wooden pallets and tied up with polypropylene band.
Name | Grade | Technical specifications and standards | Temperature index | Insulation type | Diameter range, mm | Thermoplasticity, °C | Heat shock, °C | Properties and applications |
Round copper wire with enamel insulation on the basis of polyesters | ПЕТВ-1; ПЕТВ-2 | ТУ У 27.3-38456790-007:2017 | 130
180 |
Polyester | 0,06÷1,60
0,06÷2,50 |
180±5
200±5 |
155±5 | For winding of electric machines, apparatuses and devices |
Copper winding wires are designed for winding of electric motors stators, transformers, electromagnetic relay, coils of oscillating circuits of products with maximum thermal and mechanical loads and also for winding of electric machines and devices
Copper winding wires can be used either for mechanical or manual winding.
The wires are manufactured on the modern equipment of the Austrian manufacturer MAG AG using the insulating materials of the French company IVA ESSEX SAS. Packing of the final products is performed on spools K-125/K-250 according to IEC 60264-2, A-200/A-400 according to IEC 60264-3 (winding up to 200 kg), placed on the wooden pallets and tied up with polypropylene band.
Name | Grade | Technical specifications and standards | Temperature index | Insulation type | Diameter range, mm | Thermoplasticity, °C | Heat shock, °C | Properties and applications |
Round copper winding wire with enamel insulation on the basis of polyester or polyetherimide and external coating on the basis of polyamide-imid | ПЕТД-180; ПЕТД-200 | ТУ У 27.3-38456790-006:2017 | 180
200 |
Polyester (polyetherimide) + polyamide-imid | 0,224÷2,5 | 265±5
290±5 |
200±5
220±5 |
For winding of electric machines, apparatuses and devices |
Copper winding wires are designed for winding of electric motors stators, transformers, electromagnetic relay, coils of oscillating circuits of products with maximum thermal and mechanical loads and also for winding of electric machines and devices
Copper winding wires can be used either for mechanical or manual winding.
The wires are manufactured on the modern equipment of the Austrian manufacturer MAG AG using the insulating materials of the French company IVA ESSEX SAS. Packing of the final products is performed on spools K-125/K-250 according to IEC 60264-2, A-200/A-400 according to IEC 60264-3 (winding up to 200 kg), placed on the wooden pallets and tied up with polypropylene band.
Name | Grade | Technical specifications and standards | Temperature index | Insulation type | Diameter range, mm | Thermoplasticity, °C | Heat shock, °C | Properties and applications |
Round copper winding wire with enamel insulation on the basis of polyester or polyetherimide and external coating on the basis of polyamide-imid, class 200 |
ПЕТД-2-200 | ТУ У 27.3-38456790-009:2017 | 200 | Polyester (polyetherimide) + polyamide-imid | 0,05÷2,50 | 320±5 | 220±5 | Designed for use in products that work with coolants in mixtures with refrigeration oils |
Standard | Cu, %, no less | Cross section, mm² | Construction | Electrical resistance/1 km, Ohm, not more | Breaking strength of the wire, N, not less than |
ТУ У 27.4-20006134-028-2004 | 99,9 | 0,75 | (1+6) x 28 x 0,071 | 32,0 | 139,6 |
1 | 4 x 2 x 30 x 0,071 | 25,0 | 170,9 | ||
1,25 | 5 x 2 x 30 x 0,071 | 20,0 | 213,7 | ||
1,5 | (1+6) x 2 x 28 x 0,071 | 17,0 | 279,2 | ||
1,6 | (1+6) x 2 x 30 x 0,071 | 14 | 299,1 | ||
2 | 6 x 3 x 30 x 0,071 | 11 | 384,6 | ||
2,5 | (1+6) x 3 x 30 x 0,071 | 9,6 | 448,7 | ||
3,2 | (1+6) x 4 x 30 x 0,071 | 7,2 | 598,2 | ||
4,0 | (1+6) x 43 x 0,13 | 5,0 | 718,7 | ||
6,0 | (3+9) x 38 x 0,13 | 3,5 | 1088,9 | ||
8,0 | (1+6+12) x 33 x 0,13 | 2,4 | 1497,2 | ||
10,0 | (1+6+12) x 39 x 0,13 | 2,0 | 1769,4 | ||
12,5 | (3+9) x 2 x 39 x 0,13 | 1,6 | 2235,0 | ||
16,0 | (3+9) x 2 x 36 x 0,13 | 1,2 | 3094,0 |
Standard | Cu, %, not less than | Cross-section, mm² | Class | Wire diameter, mm | Deviation of the diameter |
ДСТУ EN 60228:2015 (grade: 1, 2, 5)
ГОСТ 22483-78 (grade 3, 4) |
99,90 | 0,5-1,0 | 5 | 0,200 | ± 1% |
1,5-2,5 | 5 | 0,250 | |||
4,0-6,0 | 5 | 0,320 | |||
10,0-50,0 | 5 | 0,405 | |||
70,0-240,0 | 5 | 0,505 | |||
0,5-1,0 | 4 | 0,320 | |||
1,5-2,5 | 4 | 0,405 | |||
4,0-6,0 | 4 | 0,505 | |||
10,0-95,0 | 4 | 0,505 | |||
120,0-240,0 | 4 | 0,675 | |||
1,0 | 3 | 0,405 | |||
1,5 | 3 | 0,505 | |||
2,5 | 3 | 0,675 | |||
4,0-6,0 | 3 | 0,845 | |||
10,0-95,0 | 3 | 0,670 | |||
120,0-240,0 | 3 | 0,845 | |||
10,0-240,0 | 2 |
Cross-section, mm² | 0,5-2,0 | 0,5-35,0 | 25,0-95,0 | 120,0-240,0 | ||||||||
Packing: | Drum | Drum | Drum | Drum | ||||||||
Packing material: | Metal | Metal | Wooden | Wooden | ||||||||
Outer diameter, mm | 400 | 630 | 1000 | 1400 | ||||||||
Axis hole, mm | 56 | 56/127 | 80 | 80 | ||||||||
Net weight, kg | 110 | 440 | 1000 | 1850 | ||||||||
Gross weight, kg | 140 | 510 | 1100 | 2000 |
Standard | Cu, %, not less t han | Wire diameter, mm | Deviation of the diameter, mm | Mechanical parameters | ||||||||||
Relative elongation of wire, %, not less than | Temporary tensile strength of wire, MPa, not less than | |||||||||||||
ТУ У 27.4 – 33361757 – 003 : 2010 | 99,90 | 0,8 | ± 0,02 | 30 | 196-284 | |||||||||
1,25 | ± 0,02 | 30 | 196-284 | |||||||||||
1,38 | ± 0,02 | 30 | 196-284 | |||||||||||
1,50 | ± 0,02 | 30 | 196-284 | |||||||||||
1,80 | ± 0,02 | 30 | 196-284 |
Wire diameter, mm | 1,20-1,80 | 1,20-1,80 | |||
Packing: | Drum | Container | |||
Outer diameter, mm | 630 | 875 | |||
Axis hole, mm | 56/127 | 450 | |||
Net weight, kg | 600 | 800 | |||
Gross weight, kg | 690 | 830 |
Standard | Cu, %, not less than | Wire diameter, mm | Deviation of the diameter | Mechanical properties | |
Relative elongation of wire,%, not less than | Temporary tensile strength of wire, MPa, not less than | ||||
ДСТУ EN 13602:2010 | 99,9 | 0,15-0,25 | ± 0,003 мм | 21 | 200 |
0,32-0,52 | ± 0,004 мм | 22 | 200 | ||
0,64-1,05 | ± 1% | 24 | 200 | ||
1,05-1,50 | ± 1% | 26 | 200 | ||
1,50-3,00 | ± 1% | 28 | 200 | ||
3,00-5,00 | ± 1% | 33 | 200 |
Wire diameter, mm | 0,15-0,20 | 0,25-1,05 | 1,13-5,00 | 1,13-2,76 |
Packing: | Drum | Drum | Drum | Container |
Packing material: | Silumin | Metal | Metal | Cardboard |
Outer diameter, mm | 170/310 | 360 | 630 | 875 |
Axis hole, mm | 100/200 | 200 | 56/127 | 450 |
Net weight, kg | 40 | 90 | 600 | 800 |
Gross weight, kg | 50 | 110 | 690 | 830 |
Standard | Al, %, not less than | Cross-section, mm² | Class |
ДСТУ EN 60228:2015 | 99,85 | 10,0 – 240,0 | 2 |
Cross-section, mm² | 10,0-35,0 | 25,0-95,0 | 120,0-240,0 |
Packing: | Drum | Drum | Drum |
Packing material: | Metal | Wooden | Wooden |
Outer diameter, mm | 630 | 1000 | 1400 |
Axis hole, mm | 56/127 | 80 | 80 |
Net weight, kg | 150 | 400 | 900 |
Gross weight, kg | 235 | 450 | 1000 |
Standard | Al, %, not less than | Wire diameter, mm | Deviation of the diameter, mm | Mechanical properties | |||||
Relative elongation of wire, %, not less than | |||||||||
ТУ У 24.4-33361757-005:2012 | 99,70 | 1,30-2,44 | ± 0,02 | 20 | |||||
2,44-3,45 | ± 0,03 | 20 | |||||||
3,45-4,37 | ± 0,04 | 20 | |||||||
4,37-6,60 | ± 0,05 | 25 |
Wire diameter, mm | 1,30-6,60 | |||
Packing: | Drum | |||
Outer diameter, mm | 630 | |||
Axis hole, mm | 56/127 | |||
Net weight, kg | 150 | |||
Gross weight, kg | 240 |
Nominal cross section of the strand, mm2 | Nominal radial thickness of insulation, mm | The maximum resistance of the conductor at a temperature of 20ºC, Ohm/km | ||
PV1*,
PV1ng |
PV2**
PV2ng |
PV3***
PV3ng |
||
0,5 | 0,6 | 36,0 | – | 39,0 |
0,75 | 0,6 | 24,5 | – | 26,0 |
1,0 | 0,6 | 18,1 | – | 19,5 |
1,5 | 0,7 | 12,1 | 12,1 | 13,3 |
2,5 | 0,8 | 7,41 | 7,41 | 7,98 |
4,0 | 0,8 | 4,61 | 4,61 | 4,95 |
6,0 | 0,8 | 3,08 | 3,08 | 3,30 |
10,0 | 1,0 | 1,83 | 1,83 | 1,91 |
16,0 | 1,0 | – | 1,15 | 1,21 |
25,0 | 1,2 | – | 0,727 | 0,780 |
35,0 | 1,2 | – | 0,524 | 0,554 |
50,0 | 1,4 | – | 0,387 | 0,386 |
70,0 | 1,4 | – | 0,268 | 0,272 |
95,0 | 1,6 | – | 0,193 | 0,206 |
120,0 | 1,6 | – | 0,153 | 0,161 |
* PV-1 – flexibility class 1. ** PV-2 – flexibility class 2. *** PV-3 – flexibility class 5. |
Brands of wires | Name of wires and their elements | The predominant usage |
PV1 | Installation wire with copper strand (single-wire), with polyvinyl chloride isolation | For not flexible installation of electrical circuits |
PV2 | Installation wire with copper strand (multi-wire), with polyvinyl chloride isolation, flexible | For installation of electric circuits on sites where bends of wires are possible |
PV3 | Installation wire with copper strand (multi-wire), with polyvinylchloride isolation, with increased flexibility | For installation of electrical circuits in areas where frequent bending of wires during installation is possible. |
PV1ng | Installation wire with copper strand (single-wire), with polyvinyl chloride isolation, with reduced flammability | For not flexible installation of electric circuits where the increased requirements to not spreading of burning are shown |
PV2ng | Installation wire with copper strand (multi-wire), with polyvinyl chloride isolation of reduced flammability, flexible | Similar to PV1ng for areas where bending of wires is possible |
PV3ng | Installation wire with copper strand (multi-wire), with polyvinyl chloride isolation of reduced flammability, with increased flexibility | Similar to PV2ng for areas where frequent bending of wires during installation is possible. |
Number and nominal cross section of strands, mm2 | Nominal thickness, mm | Number and nominal cross section of strands, mm2 | Nominal thickness, mm | The maximum resistance of the conductor at a temperature of 20º C
(Flexibility class 5), Ohm/km |
||
Isolation | Shell | Isolation | Shell | |||
2х0,5 | 0.5 | 0.6 | 3х0,5 | 0.5 | 0.6 | 39.0 |
2х0,75 | 0.5 | 0.6 | 3х0,75 | 0.5 | 0.6 | 26.0 |
2х1,0 | 0.6 | 0.8 | 3х1,0 | 0.6 | 0.8 | 19.5 |
2х1,5 | 0.7 | 0.8 | 3х1,5 | 0.7 | 0.8 | 13.3 |
2х2,5 | 0.8 | 1.0 | 3х2,5 | 0.8 | 1.0 | 7.98 |
2х4,0 | 0.8 | 1.2 | 3х4,0 | 0.8 | 1.2 | 4.95 |
2х6,0 | 0.8 | 1.2 | 3х6,0 | 0.8 | 1.2 | 3.30 |
Name of wires | The predominant usage |
The wire is flexible with parallel copper strands, with polyvinyl chloride isolation, in a lightweight of polyvinyl chloride shell. | For flexible connection of household appliances, equipment, lamps, extension cords, which are used in the house and industrial premises to electrical networks at a nominal AC voltage up to 380 V (for 380/380 V systems). |
Number and nominal cross section of strands, mm2 | Nominal thickness, mm | Number and nominal cross section of strands, mm2 | Nominal thickness, mm | The maximum resistance of the conductor at a temperature of 20ºC
(Flexibility class 5), Ohm/km |
||
Isolation | Shell | Isolation | Shell | |||
2х0,75 | 0,6 | 0,8 | 4х0,75 | 0,6 | 0,8 | 26.0 |
2х1,0 | 0,6 | 0,8 | 4х1,0 | 0,6 | 0,9 | 19.5 |
2х1,5 | 0,7 | 0,8 | 4х1,5 | 0,7 | 1,0 | 13.3 |
2х2,5 | 0,8 | 1,0 | 4х2,5 | 0,8 | 1,1 | 7.98 |
2х4,0 | 0,8 | 1,2 | 4х4,0 | 0,8 | 1,4 | 4.95 |
2х6,0 | 0,8 | 1,2 | 4х6,0 | 0,8 | 1,4 | 3.30 |
2х10,0 | 1,0 | 1,4 | 4х10,0 | 1,0 | 1,4 | 1,91 |
3х0,75 | 0,6 | 0,8 | 5х0,75 | 0,6 | 0,9 | 26.0 |
3х1,0 | 0,6 | 0,8 | 5х1,0 | 0,6 | 0,9 | 19.5 |
3х1,5 | 0,7 | 0,9 | 5х1,5 | 0,7 | 1,1 | 13.3 |
3х2,5 | 0,8 | 1,1 | 5х2,5 | 0,8 | 1,2 | 7.98 |
3х4,0 | 0,8 | 1,2 | 5х4,0 | 0,8 | 1,4 | 4.95 |
3х6,0 | 0,8 | 1,4 | 5х6,0 | 0,8 | 1,4 | 3.30 |
3х10,0 | 1,0 | 1,4 | 5х10,0 | 1,0 | 1,4 | 1,91 |
Brands of wires | Name of wires | The predominant usage |
PVS | Flexible wire with twisted copper strands insulated with polyvinyl chloride, with polyvinyl chloride shell | For flexible connection of electric household machines, equipment, devices and manual power tools, extension cords to electric networks on nominal alternating voltage up to 380 V (for systems 380/660 V) |
PVSng | Similar to PVS brand wires, with a low-flammability polyvinyl chloride shell | Similar to PVS brand wires in conditions where there are increased requirements for not spreading of wire burning |
PVSng-LS | Similar to PVS brand wires, with isolation and shell of low-flammability polyvinyl chloride | Similar to PVSng wires, in conditions where low formation of smoke and corrosive gases during burning and smoldering is additionally required |
Cable brand | Number of insulated
Strands |
Nominal cross-section of the main strands, mm | |
0,38/0,66 | 0,6/1(1,2) | ||
VVG, VVGng, VVGng–LS | 1,2,3,4,5 | 1,5-50 | 1,5-240 |
VVG–P, VVGng P, VVGng–LS–P | 2,3 | 1,5-16 | 1,5-16 |
VVGz, VVGzng, VVGzng – LS | 2,3,4,5 | 1,5-50 | 1,5-240 |
Note 1. Marking:
z – between strand filling; ng – not spreading of burning, including in the case of laying in beams; LS – low smoke – and gas formation during burning and smoldering. Note 2. Multicore cables shall have all strands of the same cross-section. Four-core cables can have one core of smaller cross-section (zero or ground). Five-core cables may have two cores of smaller cross-section (zero and ground). |
Nominal cross section of the strand, mm2 | The maximum resistance of the conductor at a temperature of 20ºC
(Flexibility class 1; 2), Ohm/km |
1,5 | 12,1 |
2,5 | 7,41 |
4 | 4,61 |
6 | 3,08 |
10 | 1,83 |
16 | 1,15 |
25 | 0,727 |
35 | 0,524 |
50 | 0,387 |
70 | 0,268 |
95 | 0,193 |
120 | 0,153 |
150 | 0,124 |
185 | 0,0991 |
240 | 0,0754 |