CYKY-J(O)

(CSN 34 7411:14)
Power cables with PVC thermoplastic insulation and sheath for permanent installation
CYKY-J(O)

C Copper core cable, Class 1 (RE)
V Polyvinylchloride plastic insulation
K Cable
V Polyvinylchloride plastic coating
Lo Flat
J Cable with yellow-green core
O Cable without yellow-green core

Operating and installation requirements

  • Ambient temperature from -50°C to 50°C.
  • Relative humidity up to 98 % at temperatures up to 35°C.
  • Cables can be laid without preheating at temperatures not lower than –15°C.
  • Minimum bending radius during installation should be not less than 10 outer diameters of a single core cable and 7.5 outer diameters of a multi-core cable.
  • Long-term temperature rise limits for cable cores should not exceed 70°C.
  • Temperature limit in the overload mode is max 90°C.
  • Rated alternating voltage up to 450/750 V.
  • Warranty service life is 5 years.
  • Service life is minimum 30 years.

Wires intended use
CYKY-J(O)

Cables are intended for transmission and distribution of electric power in permanent equipment for 450/750 V nominal AC voltage and 50 Hz frequency.

It is recommended to use the given cable type for concealed wiring and individual laying in rectangular cable ducts of appropriate dimensions. Not recommended to be laid in the ground (in trenches)

Conductor design
CYKY-J(O)

  Core count Rated voltage, V Backbone cores nominal cross-section, mm2

CYKY-J(O)

2, 3, 4, 5 450/750 1,5 - 6
  4, 5   10

Design data for
CYKY-J(O)wires

Core nominal cross-section, mm2 Nominal thickness, mm Nominal cable diameter, mm Maximum wire resistance at 20°C, Ohm/km Minimum value of insulation resistance at 70°C, MOhm/km Calculated mass of 1 km cable, kg
insulation sheath CYKY-J(O)
2х1,5 RE 0,7 1,0 7,9 12.531 0.011 104
2х2,5 RE 0,8 1,0 9,1 7.52 0.010 146
2х4 RE 0,8 1,0 10,0 4.70 0.0085 192
2х6 RE 0,8 1,0 11,0 3.133 0,0070 251
3х1,5 RE 0,7 1,0 8,3 12.531 0.011 122
3х2,5 RE 0,8 1,0 9,6 7.52 0.010 174
3х4 RE 0,8 1,0 10,5 4.70 0.0085 233
3х6 RE 0,8 1,0 11,6 3.133 0,0070 311
4х1,5 RE 0,7 1,0 9,0 12.531 0.011 147
4х2,5 RE 0,8 1,0 10,4 7.52 0.010 213
4х4 RE 0,8 1,0 11,5 4.70 0.0085 286
4х6 RE 0,8 1,0 12,8 3.133 0,0070 384
4х10 RE 1,0 1,2 15,7 1.88 0,0070 609
5х1,5 RE 0,7 1,0 9,8 12.531 0.011 173
5х2,5 RE 0,8 1,0 11,4 7.52 0.010 252
5х4 RE 0,8 1,0 12,6 4.70 0.0085 341
5х6 RE 0,8 1,0 14,0 3.133 0,0070 460
5х10 RE 1,0 1,2 17,7 1.88 0,0070 750

Note: Calculated and nominal data can deviate from the actual data.
Identification markings meet fire safety requirements under CSN 50575 (EN 50575) CYKY-J(O) Eca